What it is for
- Use it when you need repeating ON/OFF output timing.
- You can define the ON time, OFF time, units, number of cycles, trigger mode, and trigger edge.
repeatCount = 0means run forever.
Main fields
On Time
Duration of the ON phase.
Off Time
Duration of the OFF phase.
Units
Each time can use
ms, s, or Min.Number of Cycles
How many ON/OFF repetitions to run. Zero means infinite.
Trigger Mode
Manual shows Start/Stop/Reset buttons. External waits for the trigger input.
Trigger Edge
Select Rising or Falling for the external trigger input.
Manual and external trigger behavior
Manual trigger mode [Start] [Stop] [Reset] External trigger mode External Trigger
- In Manual mode, start and stop the timer from the Timer Screen or the web page.
- In External mode, the Timer Screen hides the action buttons and shows External Trigger.
Warp Speed
- When enabled, one real second advances the cyclic runtime by 60 seconds for phases using
sorMin. - If either cyclic unit is set to
Min, warp acceleration remains active across both phases. - The countdown still looks normal in
MMM:SSformat. - The Cycles tile also shows Warp mode.
- Warp Speed is forced back to Disabled on every reboot.
Where to edit it
Use the Cyclic Timer Settings Menu on the TFT display or the Web UI.